SB-909
TS-940S AVR Unit Capacitor Change 4-8-86
In those areas of the country that are subject to large poer line voltage
fluctuations, excessive voltage may be applied to capacitor C12 on the AVR
Unit (X43-1500-00). These voltage fluctuations might exceed the capacitor
breakdown voltage. Replacing capacitor C12 with a capacitor having a
higher breakdown voltage will help prevent this potential problem.
Procedure:
On the AVR Unit change C12 from a 6800 uF capacitor to a 5600 uF 25V
capacitor (C90-2037-05).
Time required for this modification is 1 hour or less.
(c) 121589TKC